<LOGO>
FM Transmitter Measurement Report
Created: 2025-05-20 07-30-21
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 5/5, 53 dBuV VOLTAGE
Pilot RDS Phase Difference
6.5 kHz 4.1 kHz -11 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
13 kHz 71 kHz 10038 1,3150
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
5,9 dBr 7,33 dBr 8,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 7:30, 20.05.2025
RT
"VOLTAGE - Addictive Radio "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 5/5 (55 dBuV) Max at: 71 kHz MIN: 13 kHz % above 75 kHz: 1,3150 Acquired: 2025/05/20 7:29:17 Total samples: 10038 Equivalent time: 0:08:21 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 8,1 dBr MIN: 5,9 dBr AVE: 7,33 dBr % above 10,2 dBr: 0,0 Last value: 8,1 dBr (2025/05/20 7:29:17) Station: 96.90 MHz, signal: 5/5 (55 dBuV) 07:22 07:23 07:24 07:25 07:26 07:27 07:28 07:29 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality